SOUND CONTROL ASSEMBLY : PGD-W6-467-24

ASSEMBLY COMPONENTS

  • Acoustical

    STC 53

    NOAL 22-0760

  • Fire

    1 hr.

    U309

  • Dimensions

    Thickness: 6-3/4"

    Approx. Weight: 7.4 lb/ft²

  • Bearing

    Load Bearing

ASSEMBLY DETAILS

  • 1-7/8’’ Type W drywall screws spaced 7” o.c. (for fire, minimum 1-5/8” screws spaced 12” o.c. at edges and 8” o.c. in the field).
  • One layer: 5/8” QuietRock® 530 or QuietRock® 530 RF gypsum panel applied vertically.
  • 2 x 6 wood studs 24” o.c.
  • 6”, R-19 glass fiber insulation friction fit into stud cavity. 
  • One layer: 5/8” QuietRock® 530 or QuietRock® 530 RF gypsum panel applied vertically.
  • 1-7/8’’ Type W drywall screws spaced 7” o.c. (for fire, minimum 1-5/8” screws spaced 12” o.c. at edges and 8” o.c. in the field).